Procedure of Measurement of coating thickness- ISO 2360
6 Procedure of Measurement of coating thickness 6.1 Calibration of instruments 6.1.1 General Before use, each instrument shall be calibrated in accordance with the manufacturer’s instructions, using suitable calibration standards. Particular attention shall be paid to the description given in Clause 3 and to the factors described in Clause 5. In order to minimize conductivity changes due to temperature variations, at the time of calibration the instrument and the calibration standards shall be at a temperature close to the temperatureRead More …